Alphatemp Technology

BASKET | CHECKOUT | Items:, Value:

Call Us: + 44/0 1376 344679
 
 

USB PT-104

REF: KI-PP682
 
ACCURACY AND RESOLUTION

Although accurate temperature sensors are widely available, it has been difficult to find a measuring device that can take advantage of them without introducing excessive errors. The PT-104 USB, however, is inherently accurate due to its novel design. Rather than relying on voltage references (which tend to be temperaturesensitive) it uses ‘reference’ resistors which are extremely stable (low temperature coefficient and drift). The exact value of each resistor is stored in an EEPROM to provide the ultimate in accuracy (yearly recalibration is recommended). To achieve the 0.001°C resolution, a highly advanced ADC is used that can resolve to better than 1 part in 16 million.

TEMPERATURE

The PT-104 USB measures temperature using platinum resistance thermometers (PRTs). Both common industry standards (PT100 and PT1000) are supported. The unit is compatible with 2, 3 and 4 wire sensors (4 wire PT100 sensors are recommended for accurate measurements). A wide range of PT100 sensors are available for use with the PT-104.

- MEASURES TEMPERATURE, RESISTANCE AND VOLTAGE

- HIGH RESOLUTION AND ACCURACY

- CONNECT VIA USB OR ETHERNET PORT 

USB PT-104
 
ModelDescriptionPrice
 
Ref: KI-PP682  USB PT-104      459.00 
 
Qty:    
 
 
 
 

PT-104 Terminal board

REF: 3235
 
The PT-104 Screw Terminal Adapter is an accessory for the PT-104 Platinum Resistance Data Logger. The adapter allows PT100 probes that are not fitted with a mini-DIN connector to be used with the data logger without the need for any soldering.
 

PT-104 Terminal board
 
ModelDescriptionPrice
 
Ref: 3235  PT-104 Terminal board      7.00 
 
Qty:    
 
 
 
 

TC-08

REF: KI-PP222
 
- 8 CHANNEL THERMOCOUPLE DATA LOGGER
- MEASURES FROM -270°C TO +1820°C
- AUTOMATIC COLD CONJUNCTION COMPENSATION
- HIGH RESOLUTION AND ACCURACY

Channels 8
Resolution 20 bits
Input range ±70 mV
Conversion time 100 ms
Temperature accuracy Sum of ±0.2 % of reading and ±0.5°C
Voltage accuracy Sum of ±0.2 % of reading and ±10 ìV
Thermocouple types supported B, E, J, K, N, R, S, T 

TC-08
 
ModelDescriptionPrice
 
Ref: KI-PP222  TC-08     289.00 
 
Qty:    
 
 
 
 

TC-08 Terminal board

REF: PP624
 
This is an optional terminal board for the TC-08. The screw terminals allow wires to be attached to the data logger without soldering and enable the TC-08 to measure voltages from 0 to +5 V, or 4-20 mA loop current. 

TC-08 Terminal board
 
ModelDescriptionPrice
 
Ref: PP624  TC-08 Terminal board      21.00 
 
Qty:    
 
 
 
 

KI-DR.DAQ Data-Logger

REF: KI-DR.DAQ
 

Ki-Dr.Daq Data-Logger has built in sensors for Light - Sound and Temperature Measurement, it can also measure Voltage and Resistance and has a socket for standard pH Electrodes and connectors for optional external sensors.

It simply plugs into your PC and Measures with software Supplied you can use DR Daq to capture fast signals (eg. Sound Wave Forms), it also Requires no External Power Source.

Input Channels: 7 x Internal and 2 x External.
Sampling Rate: 10 to 15kS/s (PC Dependent)
Overload Protection: +/- 30V
Digital Outputs: 1 TTL (with 1 to 3k ohms Output Impedance), 1 LED.
Output Connector: 25 way male D Type to PC parallel port (cable supplied).

For Probes and Sensors please refer to Temperature Probes and pH Probes sections.

 

KI-DR.DAQ Data-Logger
 
ModelDescriptionPrice
 
Ref: KI-DR.DAQ  KI-DR.DAQ Data-Logger     95.00 
 
Qty:    
 
 

spacer
spacer